Install KSolare Solar App

Fast, native fullscreen solar monitor

Home Solar Plant 3.4 kW

KSolare 5G-PRO • Gujarat, India

🏢 Admin Fleet
ONLINE
⚡ Current Power
209
W
6.3% Load
📈
Today's Generation
7.20 kWh
This Day Generation (kWh)
₹
Today's Revenue / Savings
₹21.60
This Day Revenue (@ ₹3.00/unit)
⚡
Lifetime Generation
13,346 kWh
Total Generation
🌱
CO₂ Offset
10,944 kg
≈ 521 Trees Planted

🔌 Electrical Diagnostics

KSolare KSY 3.4KW-1Ph
Grid Voltage
230.2 V
AC Current
1.80 A
Grid Frequency
50.01 Hz
DC PV String
338.0 V
Inverter Temp
38.5 °C

⚡ Max-Yield Optimization & Inverter Tuning

Real-Time Derating Guard • KSolare Admin Portal Parameters vs Our App

🔗 KSolare ShineMonitor Portal
⚡ Grid Overvoltage Trip Guard
Normal (<245V)
230.2 V
Standard inverters trip offline at 253V. If afternoon grid voltage spikes >250V, have KSolare/installer adjust AC limit to 260V.
🌡️ Inverter Thermal Guard
Cool (<45°C)
38.5 °C
Inverter throttles output if heatsink exceeds 50°C. Keep inverter in shade with 30cm airflow to prevent midday power loss.
☀️ MPPT Voltage Band
Optimal (320V-360V)
338.0 V
Peak conversion efficiency (97.5%+) occurs at 320V-360V DC. Clean panels early morning (before 8 AM) for max DC input.

🛠️ Parameter Optimization Guide: KSolare Admin vs Our App

Parameter / Optimization In KSolare Portal (web.shinemonitor.com) In Our Custom App (Live Telemetry) Yield Impact
Reconnection Time (T_reconnect) Inverter Parameters
Change from 300s (5 min) to 60s (1 min). Recovers 4 mins faster after any minor grid drop.
Live Monitor
Displays real-time status (Online vs Offline) with instant alert when grid reconnects.
+1–2 kWh/day on grid fluctuation days
AC Overvoltage Protection Limit Protection Settings
Check if set to standard 253V. If midday tripping occurs, request KSolare/installer adjust to 260V–265V.
Overvoltage Guard
Live voltage monitoring with real-time risk alert when local DISCOM voltage exceeds 248V.
+2–4 kWh/day during peak midday sun
Power Factor (Cos φ) Grid Code Config
Ensure set to 1.0 (Unity) so 100% of solar inverter capacity produces active billable electricity (kWh).
Diagnostic Telemetry
Live voltage, current, and grid frequency monitoring to ensure zero reactive loss.
100% Active Power Guarantee
Firmware (OTA) Upgrades Remote Maintenance
Check DSP/ARM firmware version for serial number. KSolare technical support pushes OTA updates via your Wi-Fi stick logger.
1-Click Support Template
One-click "Copy Firmware Request" button generates a pre-filled support ticket with S/N & Logger ID.
+2–5% Peak MPPT Tracking Stability
Panel Cleaning & Maintenance Historical Logs
Review monthly yield decline trends.
Performance Pill & Load %
Instant Load % benchmark. Clean panels early morning (before 8 AM) with soft water when load is below expected sunny rating.
+15–25% Boost in overall monthly yield

📊 Generation History

Today
Total: 0.00 kWh • Revenue: ₹0.00
Hourly Power (Watts)

🛡️ Hardware Status & Alarms

0 Active Faults (Normal)
Protocol: KSolare 5G-PRO Modbus RTU / Solarman V5
Safety Standard: IEC 61727 Certified
Sync Mode: Real Hardware Telemetry
S/N: KSY0323HK0040 | Logger: Q0027356442775 ● Grid Synchronized & Protected